{"id":"CVE-2023-0754","aliases":[],"summary":"The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code.","published_at":"2023-02-23T21:27:09.964Z","modified_at":"2025-01-16T21:55:46.607Z","products":[{"slug":"dotnet","name":".NET / ASP.NET Core","category":"microsoft"}],"rating":{"severity":"critical","score":9.8,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","attack_path":"internet_unauthenticated","user_interaction":false,"malicious":false},"fix_available":false,"kev":{"listed":false,"ransomware":false},"public_exploit":false,"exploits":[],"epss":{"score":0.029370000585913658,"percentile":0.8744000196456909,"date":"2026-11-21T00:00:00Z"},"priority":11.8,"record_count":2,"vendors":[],"details":"The affected products are vulnerable to an integer\noverflow or wraparound, which could  allow an attacker to crash the server and remotely\nexecute arbitrary code.","affected_stack":[{"ecosystem":"CVE","package":"Microsoft/.NET-SDK","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v5.8.4.971 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"}],"affected_other":[{"ecosystem":"CVE","package":"General Electric/Digital Industrial Gateway Server","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v7.612"}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/Kepware KEPServerEX","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v6.12 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Edge C-SDK","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v2.2.12.1052 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Edge MicroServer (EMS)","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v5.4.10.0 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Industrial Connectivity","versions":["All Versions "],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Kepware Edge","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v1.5"}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Kepware Server","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v6.12 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"Rockwell Automation/KEPServer Enterprise","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v6.12"}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ge:digital_industrial_gateway_server","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"7.612"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:kepware_server","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"6.12"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:kepware_serverex","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"6.12"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:thingworx_.net-sdk","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"5.8.4.971"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:thingworx_edge_c-sdk","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"2.2.12.1052"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:thingworx_edge_microserver","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"5.4.10.0"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:thingworx_kepware_edge","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"1.5"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"rockwellautomation:kepserver_enterprise","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"6.12"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"}],"product_status":[],"records":[{"provider":"cvelistv5","source_id":"CVE-2023-0754","relation":"self","url":"https://www.cve.org/CVERecord?id=CVE-2023-0754","license":"CC-BY-4.0","published_at":"2023-02-23T21:27:09.964Z","modified_at":"2025-01-16T21:55:46.607Z","summary":"The affected products are vulnerable to an integer overflow or wraparound, which could allow an attacker to crash the server and remotely execute arbitrary code.","details":"The affected products are vulnerable to an integer\noverflow or wraparound, which could  allow an attacker to crash the server and remotely\nexecute arbitrary code.","severity":[{"type":"CVSS_V3","score":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","source":"CVE-2023-0754"}],"affected":[{"ecosystem":"CVE","package":"General Electric/Digital Industrial Gateway Server","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v7.612"}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"Microsoft/.NET-SDK","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v5.8.4.971 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/Kepware KEPServerEX","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v6.12 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Edge C-SDK","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v2.2.12.1052 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Edge MicroServer (EMS)","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v5.4.10.0 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Industrial Connectivity","versions":["All Versions "],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Kepware Edge","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v1.5"}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"PTC/ThingWorx Kepware Server","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v6.12 "}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"CVE","package":"Rockwell Automation/KEPServer Enterprise","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"v6.12"}]}],"provider":"cvelistv5","source":"CVE-2023-0754","relation":"self"}],"product_status":[],"references":[{"type":"WEB","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"}]},{"provider":"nvd","source_id":"CVE-2023-0754","relation":"self","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-0754","severity":[],"affected":[{"ecosystem":"NVD","package":"ge:digital_industrial_gateway_server","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"7.612"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:kepware_server","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"6.12"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:kepware_serverex","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"6.12"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:thingworx_.net-sdk","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"5.8.4.971"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:thingworx_edge_c-sdk","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"2.2.12.1052"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:thingworx_edge_microserver","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"5.4.10.0"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"ptc:thingworx_kepware_edge","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"1.5"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"},{"ecosystem":"NVD","package":"rockwellautomation:kepserver_enterprise","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"0"},{"last_affected":"6.12"}]}],"provider":"nvd","source":"CVE-2023-0754","relation":"self"}],"product_status":[],"references":[]}],"references":[{"type":"WEB","url":"https://www.cisa.gov/uscert/ics/advisories/icsa-23-054-01"}],"sources":[{"provider":"cvelistv5","source_id":"CVE-2023-0754","url":"https://www.cve.org/CVERecord?id=CVE-2023-0754","license":"CC-BY-4.0","modified_at":"2025-01-16T21:55:46.607Z","relation":"self"},{"provider":"nvd","source_id":"CVE-2023-0754","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-0754","relation":"self"}]}
