{"id":"CVE-2023-23779","aliases":[],"summary":"Multiple improper neutralization of special elements used in an OS Command ('OS Command Injection') vulnerabilities [CWE-78] in FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 an...","published_at":"2023-02-16T18:06:16.796Z","modified_at":"2024-10-23T14:46:56.695Z","products":[{"slug":"fortinet-other","name":"Fortinet FortiManager / FortiAnalyzer / FortiWeb / FortiMail","category":"firewall-vpn"}],"rating":{"severity":"medium","score":6.8,"vector":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:F/RL:U/RC:C","attack_path":"adjacent","user_interaction":false,"malicious":false},"fix_available":false,"kev":{"listed":false,"ransomware":false},"public_exploit":false,"exploits":[],"epss":{"score":0.013240000233054161,"percentile":0.7165200114250183,"date":"2026-11-21T00:00:00Z"},"priority":6.8,"record_count":2,"vendors":[],"details":"Multiple improper neutralization of special elements used in an OS Command ('OS Command Injection') vulnerabilities [CWE-78] in FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 and below may allow an authenticated attacker to execute unauthorized code or commands via crafted parameters of HTTP requests.","affected_stack":[{"ecosystem":"CVE","package":"Fortinet/FortiWeb","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"last_affected":"7.0.1"}]},{"type":"ECOSYSTEM","events":[{"introduced":"6.4.0"},{"last_affected":"6.4.2"}]},{"type":"ECOSYSTEM","events":[{"introduced":"6.3.6"},{"last_affected":"6.3.19"}]}],"provider":"cvelistv5","source":"CVE-2023-23779","relation":"self"}],"affected_other":[{"ecosystem":"NVD","package":"fortinet:fortiweb","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"6.3.6"},{"last_affected":"6.3.19"}]}],"versions":["6.4.0","6.4.1","6.4.2","7.0.0","7.0.1"],"provider":"nvd","source":"CVE-2023-23779","relation":"self"}],"product_status":[],"records":[{"provider":"cvelistv5","source_id":"CVE-2023-23779","relation":"self","url":"https://www.cve.org/CVERecord?id=CVE-2023-23779","license":"CC-BY-4.0","published_at":"2023-02-16T18:06:16.796Z","modified_at":"2024-10-23T14:46:56.695Z","summary":"Multiple improper neutralization of special elements used in an OS Command ('OS Command Injection') vulnerabilities [CWE-78] in FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 an...","details":"Multiple improper neutralization of special elements used in an OS Command ('OS Command Injection') vulnerabilities [CWE-78] in FortiWeb version 7.0.1 and below, 6.4 all versions, version 6.3.19 and below may allow an authenticated attacker to execute unauthorized code or commands via crafted parameters of HTTP requests.","severity":[{"type":"CVSS_V3","score":"CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:F/RL:U/RC:C","source":"CVE-2023-23779"}],"affected":[{"ecosystem":"CVE","package":"Fortinet/FortiWeb","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"last_affected":"7.0.1"}]},{"type":"ECOSYSTEM","events":[{"introduced":"6.4.0"},{"last_affected":"6.4.2"}]},{"type":"ECOSYSTEM","events":[{"introduced":"6.3.6"},{"last_affected":"6.3.19"}]}],"provider":"cvelistv5","source":"CVE-2023-23779","relation":"self"}],"product_status":[],"references":[{"type":"WEB","url":"https://fortiguard.com/psirt/FG-IR-22-133"}]},{"provider":"nvd","source_id":"CVE-2023-23779","relation":"self","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-23779","severity":[],"affected":[{"ecosystem":"NVD","package":"fortinet:fortiweb","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"6.3.6"},{"last_affected":"6.3.19"}]}],"versions":["6.4.0","6.4.1","6.4.2","7.0.0","7.0.1"],"provider":"nvd","source":"CVE-2023-23779","relation":"self"}],"product_status":[],"references":[]}],"references":[{"type":"WEB","url":"https://fortiguard.com/psirt/FG-IR-22-133"}],"sources":[{"provider":"cvelistv5","source_id":"CVE-2023-23779","url":"https://www.cve.org/CVERecord?id=CVE-2023-23779","license":"CC-BY-4.0","modified_at":"2024-10-23T14:46:56.695Z","relation":"self"},{"provider":"nvd","source_id":"CVE-2023-23779","url":"https://nvd.nist.gov/vuln/detail/CVE-2023-23779","relation":"self"}]}