{"id":"CVE-2024-52962","aliases":["WID-SEC-W-2025-0756"],"summary":"An Improper Output Neutralization for Logs vulnerability [CWE-117] in FortiAnalyzer version 7.6.1 and below, version 7.4.5 and below, version 7.2.8 and below, version 7.0.13 and below and FortiMana...","published_at":"2025-04-08T14:03:34.946Z","modified_at":"2025-04-08T22:00:00Z","products":[{"slug":"fortinet-other","name":"Fortinet FortiManager / FortiAnalyzer / FortiWeb / FortiMail","category":"firewall-vpn"}],"rating":{"severity":"medium","score":5.3,"vector":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:C","attack_path":"internet_unauthenticated","user_interaction":false,"malicious":false,"vendor_ratings":[{"source":"BSI","rating":"mittel"}]},"fix_available":false,"kev":{"listed":false,"ransomware":false},"public_exploit":false,"exploits":[],"epss":{"score":0.005229999776929617,"percentile":0.45254001021385193,"date":"2026-11-21T00:00:00Z"},"priority":7.3,"record_count":3,"vendors":["BSI"],"details":"An Improper Output Neutralization for Logs vulnerability [CWE-117] in FortiAnalyzer version 7.6.1 and below, version 7.4.5 and below, version 7.2.8 and below, version 7.0.13 and below and FortiManager version 7.6.1 and below, version 7.4.5 and below, version 7.2.8 and below, version 7.0.12 and below may allow an unauthenticated remote attacker to pollute the logs via crafted login requests.","affected_stack":[{"ecosystem":"CVE","package":"Fortinet/FortiAnalyzer","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.6.0"},{"last_affected":"7.6.1"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.4.0"},{"last_affected":"7.4.5"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.2.0"},{"last_affected":"7.2.8"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"last_affected":"7.0.13"}]}],"provider":"cvelistv5","source":"CVE-2024-52962","relation":"self"},{"ecosystem":"CVE","package":"Fortinet/FortiManager","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.6.0"},{"last_affected":"7.6.1"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.4.0"},{"last_affected":"7.4.5"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.2.0"},{"last_affected":"7.2.8"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"last_affected":"7.0.13"}]}],"provider":"cvelistv5","source":"CVE-2024-52962","relation":"self"}],"affected_other":[{"ecosystem":"NVD","package":"fortinet:fortianalyzer","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"fixed":"7.0.14"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.2.0"},{"fixed":"7.2.9"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.4.0"},{"fixed":"7.4.6"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.6.0"},{"fixed":"7.6.2"}]}],"fixed":["7.0.14","7.2.9","7.4.6","7.6.2"],"provider":"nvd","source":"CVE-2024-52962","relation":"self"},{"ecosystem":"NVD","package":"fortinet:fortimanager","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"fixed":"7.0.14"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.2.0"},{"fixed":"7.2.9"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.4.0"},{"fixed":"7.4.6"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.6.0"},{"fixed":"7.6.2"}]}],"fixed":["7.0.14","7.2.9","7.4.6","7.6.2"],"provider":"nvd","source":"CVE-2024-52962","relation":"self"}],"product_status":[{"vendor":"BSI","product":"Fortinet FortiAnalyzer <7.0.14","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiAnalyzer <7.2.9","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiAnalyzer <7.4.6","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiAnalyzer <7.6.2","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiManager <7.0.14","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiManager <7.2.9","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiManager <7.4.6","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiManager <7.6.2","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"}],"records":[{"provider":"cvelistv5","source_id":"CVE-2024-52962","relation":"self","url":"https://www.cve.org/CVERecord?id=CVE-2024-52962","license":"CC-BY-4.0","published_at":"2025-04-08T14:03:34.946Z","modified_at":"2025-04-08T14:27:48.42Z","summary":"An Improper Output Neutralization for Logs vulnerability [CWE-117] in FortiAnalyzer version 7.6.1 and below, version 7.4.5 and below, version 7.2.8 and below, version 7.0.13 and below and FortiMana...","details":"An Improper Output Neutralization for Logs vulnerability [CWE-117] in FortiAnalyzer version 7.6.1 and below, version 7.4.5 and below, version 7.2.8 and below, version 7.0.13 and below and FortiManager version 7.6.1 and below, version 7.4.5 and below, version 7.2.8 and below, version 7.0.12 and below may allow an unauthenticated remote attacker to pollute the logs via crafted login requests.","severity":[{"type":"CVSS_V3","score":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N/E:P/RL:X/RC:C","source":"CVE-2024-52962"}],"affected":[{"ecosystem":"CVE","package":"Fortinet/FortiAnalyzer","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.6.0"},{"last_affected":"7.6.1"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.4.0"},{"last_affected":"7.4.5"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.2.0"},{"last_affected":"7.2.8"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"last_affected":"7.0.13"}]}],"provider":"cvelistv5","source":"CVE-2024-52962","relation":"self"},{"ecosystem":"CVE","package":"Fortinet/FortiManager","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.6.0"},{"last_affected":"7.6.1"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.4.0"},{"last_affected":"7.4.5"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.2.0"},{"last_affected":"7.2.8"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"last_affected":"7.0.13"}]}],"provider":"cvelistv5","source":"CVE-2024-52962","relation":"self"}],"product_status":[],"references":[{"type":"WEB","url":"https://fortiguard.fortinet.com/psirt/FG-IR-24-453"}]},{"provider":"csaf-bsi","source_id":"WID-SEC-W-2025-0756","relation":"self","url":"https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2025-0756","license":"TLP:CLEAR, mirroring permitted","published_at":"2025-04-08T22:00:00Z","modified_at":"2025-04-08T22:00:00Z","summary":"Fortinet FortiAnalyzer: Schwachstelle ermöglicht Manipulation von Dateien","details":"Ein entfernter, anonymer Angreifer kann eine Schwachstelle in Fortinet FortiAnalyzer und Fortinet FortiManager ausnutzen, um Dateien zu manipulieren.\n\nFortiAnalyzer ist eine Plattform zur Protokollverwaltung, Analyse und Berichterstellung.\r\nFortiManager Security Management Appliances ermöglicht die Verwaltung von Fortinet Network Security Geräten.","severity":[{"type":"BSI","score":"mittel","source":"WID-SEC-W-2025-0756"}],"affected":[],"product_status":[{"vendor":"BSI","product":"Fortinet FortiAnalyzer <7.0.14","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiAnalyzer <7.2.9","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiAnalyzer <7.4.6","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiAnalyzer <7.6.2","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiManager <7.0.14","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiManager <7.2.9","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiManager <7.4.6","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"},{"vendor":"BSI","product":"Fortinet FortiManager <7.6.2","status":"affected","packages":[],"package_count":0,"fixed":[],"advisories":[],"provider":"csaf-bsi","source":"WID-SEC-W-2025-0756"}],"references":[{"type":"WEB","url":"https://wid.cert-bund.de/.well-known/csaf/white/2025/wid-sec-w-2025-0756.json"},{"type":"WEB","url":"https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2025-0756"},{"type":"WEB","url":"https://www.fortiguard.com/psirt/FG-IR-24-453"}]},{"provider":"nvd","source_id":"CVE-2024-52962","relation":"self","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-52962","severity":[],"affected":[{"ecosystem":"NVD","package":"fortinet:fortianalyzer","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"fixed":"7.0.14"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.2.0"},{"fixed":"7.2.9"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.4.0"},{"fixed":"7.4.6"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.6.0"},{"fixed":"7.6.2"}]}],"fixed":["7.0.14","7.2.9","7.4.6","7.6.2"],"provider":"nvd","source":"CVE-2024-52962","relation":"self"},{"ecosystem":"NVD","package":"fortinet:fortimanager","ranges":[{"type":"ECOSYSTEM","events":[{"introduced":"7.0.0"},{"fixed":"7.0.14"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.2.0"},{"fixed":"7.2.9"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.4.0"},{"fixed":"7.4.6"}]},{"type":"ECOSYSTEM","events":[{"introduced":"7.6.0"},{"fixed":"7.6.2"}]}],"fixed":["7.0.14","7.2.9","7.4.6","7.6.2"],"provider":"nvd","source":"CVE-2024-52962","relation":"self"}],"product_status":[],"references":[]}],"references":[{"type":"WEB","url":"https://fortiguard.fortinet.com/psirt/FG-IR-24-453"},{"type":"WEB","url":"https://wid.cert-bund.de/.well-known/csaf/white/2025/wid-sec-w-2025-0756.json"},{"type":"WEB","url":"https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2025-0756"},{"type":"WEB","url":"https://www.fortiguard.com/psirt/FG-IR-24-453"}],"sources":[{"provider":"cvelistv5","source_id":"CVE-2024-52962","url":"https://www.cve.org/CVERecord?id=CVE-2024-52962","license":"CC-BY-4.0","modified_at":"2025-04-08T14:27:48.42Z","relation":"self"},{"provider":"csaf-bsi","source_id":"WID-SEC-W-2025-0756","url":"https://wid.cert-bund.de/portal/wid/securityadvisory?name=WID-SEC-2025-0756","license":"TLP:CLEAR, mirroring permitted","modified_at":"2025-04-08T22:00:00Z","relation":"self"},{"provider":"nvd","source_id":"CVE-2024-52962","url":"https://nvd.nist.gov/vuln/detail/CVE-2024-52962","relation":"self"}]}